# Plan de Rack 42U — Rediseño Infraestructura CAS > **Fecha**: Junio 2026 > **Objetivo**: Reacomodar rack con nuevo equipo de datacenter, optimizar roles, red y almacenamiento --- ## 📦 Inventario de Hardware ### Equipo Actual | # | Equipo | Tipo | U | Estado | CPU | RAM | Storage | |---|---|---|---|---|---|---|---| | 1 | TYAN #1 | Rack 1U | 1U | ✅ Activo | Xeon Gold 5120 (28c) | 755 GB | ZFS Multimedia + local-lvm | | 2 | Dell T430 #1 "Cisco1" | Torre | ~4U en bandeja | ✅ Activo | Xeon E5-2609 v4 (16c) | 755 GB | local-lvm | | 3 | Dell T430 #2 "DellT430-2" | Torre | ~4U en bandeja | ✅ Activo | Xeon E5-2620 v4 (16c) | 126 GB | local-lvm | | 4 | Ryzen AI | Rackmount 4U | 4U | ✅ Activo | Ryzen 7 7700X | 32 GB | 500 GB SSD | | 5 | Switch Cisco | Rack 1U | 1U | ✅ Activo | — | — | — | | 6 | Mini PC OPNsense | Shelf 1U | 1U | ⚠️ Degradado | — | — | — | ### Equipo Nuevo (Adquirido Datacenter) | # | Equipo | Tipo | U | CPU (est.) | RAM (est.) | NIC | |---|---|---|---|---|---|---| | 7 | TYAN #2 | Rack 1U | 1U | Xeon (est.) | 64-128 GB (est.) | 1GbE | | 8 | Cisco UCS C220 #1 | Rack 1U | 1U | Xeon E5 v3/v4 | 64-128 GB (est.) | 1GbE | | 9 | Cisco UCS C220 #2 | Rack 1U | 1U | Xeon E5 v3/v4 | 64-128 GB (est.) | 1GbE | | 10 | Cisco UCS C220 #3 | Rack 1U | 1U | Xeon E5 v3/v4 | 64-128 GB (est.) | 1GbE | --- ## 🏗️ Layout de Rack 42U (Diseño Propuesto) ### Principios de Diseño 1. **Pesado abajo**: UPS, torres, gabinetes pesados en la base 2. **Flujo de calor**: Servidores de carga media en medio, ventilación arriba 3. **Accesibilidad**: Switch y firewall a altura de trabajo 4. **Expansión**: Dejar espacio libre para crecimiento ### Distribución por U ``` U42 [Blank Panel / Ventilación superior] U41 [Patch Panel RJ45 + gestión cables] U40 [Cable Management 1U] U39 [Switch Cisco 48p 1GbE] U38 [Mini PC OPNsense (shelf 1U)] U37 [Blank Panel] U36 [PDU A (trasera izquierda)] U35 [PDU B (trasera derecha)] U34 [TYAN #1 - Nodo Principal] U33 [TYAN #2 - Nodo Secundario] U32 [Cisco UCS #1 - Producción] U31 [Cisco UCS #2 - Desarrollo] U30 [Cisco UCS #3 - Storage/Backup] U29 [Blank Panel] U28 [Cable Management 1U] U27 [Blank Panel] U26 [Blank Panel] U25 [Blank Panel] U24 [Blank Panel] U23 [Blank Panel] U22 [Blank Panel] U21 [Blank Panel] U20 [Blank Panel] U19 [Blank Panel] U18 [Blank Panel] U17 [Blank Panel] U16 [Blank Panel] U15 [Blank Panel] U14 [Blank Panel] U13 [Blank Panel] U12 [Blank Panel] U11 [Blank Panel] U10 [Blank Panel] U09 [Blank Panel] U08 [Blank Panel] U07 [Blank Panel] U06 [Ryzen AI - Gabinete 4U] U05 [Ryzen AI - Continuación] U04 [Ryzen AI - Continuación] U03 [Ryzen AI - Continuación] U02 [Bandeja Dell T430 #1] U01 [Bandeja Dell T430 #2] ``` ### Vista Frontal Rack ``` +----------------------------------------+ | U42 Ventilación | | U41 Patch Panel | | U40 Cable Mgmt | | U39 [Switch Cisco 48p] | | U38 [OPNsense Mini PC] | | U37 Blank | +----------------------------------------+ | U36-U35 PDU Traseras | +----------------------------------------+ | U34 [TYAN #1] ====== Nodo Principal | | U33 [TYAN #2] ====== Nodo Secundario | | U32 [UCS #1] ====== Producción | | U31 [UCS #2] ====== Desarrollo | | U30 [UCS #3] ====== Storage/Backup | +----------------------------------------+ | U29-U07 Espacio libre (~22U) | | Futura expansión: | | - UPS de rack | | - Servidores adicionales | | - NAS/SAN dedicado | +----------------------------------------+ | U06-U03 [Ryzen AI 4U] ==== IA Bare | | U02-U01 [Dell T430 x2] ==== Torre Shelf | +----------------------------------------+ ``` ### Totales | Componente | U Usados | U Libres | |---|---|---| | Servidores Rack (5x 1U) | 5U | — | | Ryzen AI (4U) | 4U | — | | Dell T430 (2x bandeja) | 2U | — | | Switch + OPNsense | 2U | — | | Patch Panel + Cable Mgmt | 2U | — | | Ventilación + Blank | 2U | — | | **Total Usado** | **~17U** | **~25U libres** | --- ## 🎯 Roles por Servidor (Reestructuración) ### Fase 1: Asignación de Roles | Servidor | Rol | VMs/Servicios | Storage | Prioridad | |---|---|---|---|---| | **TYAN #1** (existente) | **Nodo Principal PVE + NAS** | OMV, Caddy, Gitea, n8n, Jellyfin, Hotel Hacienda, Immich, Navidrome | ZFS Multimedia + local-lvm | Crítico | | **TYAN #2** (nuevo) | **Nodo Secundario PVE + Replica** | Backups, replicas ZFS, servicios failover, Orchestrator | local-lvm | Alto | | **UCS #1** | **Nodo Producción PVE** | Odoo, Horux, Nexus Autopartes, NodeBB, MSP, 3D, CrawlAI | local-lvm + NFS de TYAN1 | Crítico | | **UCS #2** | **Nodo Desarrollo PVE** | Afterlife, OpenWebUI, ClaudeVM, CarlosVM, VMs dev/test | local-lvm | Media | | **UCS #3** | **Nodo Storage/Backup PVE** | TrueNAS/OMV secundario, backup target, sync | local-lvm (alta capacidad) | Media | | **Dell T430 #1** | **Retirar de PVE → Compute spare** | Migrar VMs a UCS, dejar como nodo standby | local-lvm | Baja | | **Dell T430 #2** | **Retirar de PVE → Compute spare** | Migrar VMs a UCS, dejar como nodo standby | local-lvm | Baja | | **Ryzen AI** | **Bare metal IA dedicado** | Ollama, Hermes, Kokoro TTS (mantener fuera de cluster) | Local SSD | Media | | **Mini PC OPNsense** | **Firewall perimetral** | Mantener hasta migrar a VM HA en futuro | USB/SSD | Crítico | ### Fase 2: Migración de VMs **De Dell T430 #1 (Cisco1) → UCS #2 (Desarrollo):** | VM | Destino | Notas | |---|---|---| | AfterlifeProject (106) | UCS #2 | Producción web | | OpenWebUI (101) | UCS #2 | Interfaz AI | | HermesJesus (104) | UCS #2 | Agente Hermes | | Nexterm (107) | UCS #2 | Terminal | | OnboardingNexusDB (108) | UCS #2 | DB Nexus | | ClaudeVM (109) | UCS #2 | Ya está aquí | | CarlosVM (110) | UCS #2 | Ya está aquí | **De Dell T430 #2 → UCS #1 (Producción):** | VM | Destino | Notas | |---|---|---| | CocinaConAlma (101) | UCS #1 | Tandoor | | Odoo (102) | UCS #1 | ERP | | NodeBB (103) | UCS #1 | Foro (corregir VLAN) | | Autopartes (104) | UCS #1 | Nexus e-commerce | | 3D (105) | UCS #1 | STL Manager | | CAS-PaginasWeb (106) | UCS #1 | Web CAS | | CrawlAI (107) | UCS #1 | Crawler | | Horux (108) | UCS #1 | Finanzas | | MSP (113) | UCS #1 | MeshCentral | **De TYAN #1 → TYAN #2 (Replicas/Backups):** | VM | Destino | Notas | |---|---|---| | Orchestrator (1000) | TYAN #2 | Orquestador | | NexusManager (200) | TYAN #2 | VM general | | UptimeKuma (110) | TYAN #2 | Monitoreo | | Dashy (102) | TYAN #2 | Dashboard | **Mantener en TYAN #1:** | VM | Notas | |---|---| | OMV (100) | NAS físico | | Dockge (106) | Caddy + Docker stack | | Immich (104) | Fotos (mucha I/O en ZFS) | | Hotel Hacienda (105) | Servicio crítico | | n8n (108) | Automatización | | Navidrome (109) | Música | | Metabase (111) | Analytics | | Gitea (112) | Git | --- ## 🔌 Red y Cableado ### VLANs Propuestas (Implementar en Switch Cisco) | VLAN | Rango | Uso | Puertos Switch | |---|---|---|---| | VLAN 1 (Native) | 192.168.10.0/24 | Infraestructura principal, Proxmox, servicios | 1-24 | | VLAN 20 | 192.168.20.0/24 | Usuarios/Oficina | 25-36 | | VLAN 30 | 192.168.30.0/24 | Foros/BBDD/NodeBB | 37-40 | | VLAN 40 | 192.168.40.0/24 | IoT/Invitados/Impresoras | 41-44 | | VLAN 50 | 192.168.50.0/24 | Management (IPMI, iDRAC, switch admin) | 45-48 | | VLAN 99 | — | Trunk/Inter-switch | 49-50 (SFP si aplica) | ### Cableado (Patch Panel → Switch) | Puerto Switch | Destino | VLAN | Tipo | |---|---|---|---| | 1-2 | TYAN #1 (eno1, eno2) | Trunk (1,20,30,40,50) | Cat6 | | 3-4 | TYAN #2 (eno1, eno2) | Trunk | Cat6 | | 5-6 | UCS #1 (LOM1, LOM2) | Trunk | Cat6 | | 7-8 | UCS #2 (LOM1, LOM2) | Trunk | Cat6 | | 9-10 | UCS #3 (LOM1, LOM2) | Trunk | Cat6 | | 11-12 | Dell T430 #1 (vmbr0) | Trunk | Cat6 | | 13-14 | Dell T430 #2 (vmbr0) | Trunk | Cat6 | | 15-16 | Ryzen AI (eth0) | VLAN 1 | Cat6 | | 17 | OPNsense (LAN) | Trunk | Cat6 | | 18 | OPNsense (WAN) | VLAN 1 (passthrough modem) | Cat6 | | 19-24 | Reserva servidores | — | Cat6 | | 25-36 | Usuarios oficina | VLAN 20 | Cat6 | | 37-40 | NodeBB, DBs | VLAN 30 | Cat6 | | 41-44 | IoT, impresoras | VLAN 40 | Cat6 | | 45-48 | IPMI/iDRAC switches | VLAN 50 | Cat6 | ### Diagrama de Red Objetivo ``` INTERNET | +-------+-------+ | Modem ISP | | 192.168.10.254| +-------+-------+ | +-------+-------+ | OPNsense | | Mini PC | | (Firewall) | +-------+-------+ | +-------+-------+ | Switch Cisco | | 48p (VLANs) | +-------+-------+ | +--------+-----------+-----------+--------+--------+ | | | | | | +---v---+ +--v---+ +---v---+ +--v---+ +--v---+ +--v---+ | TYAN1 | |TYAN2| | UCS#1 | |UCS#2 | |UCS#3 | | Ryzen| | PVE | | PVE | | PVE | | PVE | | PVE | | AI | | NAS | |Repl | | Prod | | Dev | | Stor | | Bare | +-------+ +-----+ +-------+ +------+ +------+ +------+ | | | | | | +--------+-----------+-----------+--------+--------+ | +--------+--------+ | Dell T430 x2 | | (Standby/Spare) | +-----------------+ ``` --- ## ⚡ Alimentación ### PDU Recomendadas | PDU | Ubicación | Conexión | |---|---|---| | PDU A (izquierda trasera) | U36 | Circuito A (20A) | | PDU B (derecha trasera) | U35 | Circuito B (20A) | ### Balanceo de Carga | PDU A | PDU B | |---|---| | TYAN #1 | TYAN #2 | | UCS #1 | UCS #2 | | Dell T430 #1 | Dell T430 #2 | | Ryzen AI | UCS #3 | | Switch Cisco | OPNsense | ### UPS (Recomendado Futuro) | Modelo Sugerido | Capacidad | Carga Estimada | |---|---|---| | APC Smart-UPS SRT 3000VA | 2700W | ~1500W rack completo | | CyberPower PR3000LCDRTXL2U | 3000VA | Rack 2U | --- ## 🚀 Roadmap de Implementación ### Fase 1: Preparación (Semana 1) - [ ] Auditar specs exactas de Cisco UCS C220 (CPU, RAM, discos, NICs) - [ ] Instalar riels en rack - [ ] Instalar PDUs y cableado de alimentación - [ ] Instalar patch panel y cableado estructurado - [ ] Etiquetar todos los cables - [ ] Instalar TYAN #2 y UCS #1/#2/#3 en rack ### Fase 2: Configuración Base (Semana 2) - [ ] Instalar Proxmox 8.x en TYAN #2 y los 3 UCS - [ ] Configurar VLANs en switch Cisco - [ ] Configurar trunk en vmbr0 de todos los nodos - [ ] Crear cluster Proxmox (5 nodos rack) - [ ] Configurar Ceph o ZFS compartido (evaluar) ### Fase 3: Migración VMs (Semana 3) - [ ] Migrar VMs de Dell T430 #1 → UCS #2 - [ ] Migrar VMs de Dell T430 #2 → UCS #1 - [ ] Mover replicas/secundarios a TYAN #2 - [ ] Validar servicios post-migración ### Fase 4: Optimización (Semana 4) - [ ] Retirar Dell T430 del cluster Proxmox - [ ] Configurar backups automatizados a UCS #3 - [ ] Implementar monitoreo de rack (temperatura, PDU) - [ ] Documentar rack físico con fotos y diagramas --- ## 📝 Notas Importantes ### Sobre los Dell T430 - Son servidores torre de ~17" de alto - En bandeja de rack ocupan ~2U cada uno pero la profundidad puede ser un problema - Considerar quedarse solo con los 5 servidores rack y vender/mover los Dell - O usar los Dell como "cold spare" (apagados, listos para emergencia) ### Sobre la Red - Switch Cisco 48p es 1GbE — suficiente para carga actual - Los Cisco UCS C220 pueden tener 10GbE SFP+ en LOM - Si se habilita 10GbE, considerar un switch de core SFP+ en el futuro - Por ahora, todo a 1GbE con VLANs es suficiente ### Sobre Almacenamiento - TYAN #1 tiene ZFS Multimedia (excelente) - UCS #3 puede montar TrueNAS/OMV como storage secundario - Ceph requiere al menos 3 nodos con storage dedicado - Alternativa: NFS/iSCSI desde TYAN #1 a los UCS --- *Plan de rack - Consultoria-AS* *Junio 2026*